GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2006-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 08/15/13. Specifications subject to change without notice.
PAGE 3 OF 3
PDPH-4-SHADE
PDPH 70M 4WG
MHC70/C/U/MP/3X LAMP, 6300 RATED LUMENS, 1.4 S/MH, TEST NO. LTL14932
PHOTOMETRY
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
4” PDPH
Elevations
®
with Glass Shade
Performance Downlight Pendant, ED17 Lamp
Zone Lumens % Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
563.3
909.3
1634.7
2798.6
2031.0
4829.7
8.9
14.4
25.9
44.4
32.2
*76.7
*E fficiency
50°
60°
70°
80°
90°
100°
0
0
0
0
0
0
pc
pw
80% 70% 50%
50%30% 50% 30% 50%30%
1
2
3
4
5
6
7
8
9
10
.69
.59
.51
.45
.40
.36
.32
.29
.27
.24
.65
.53
.44
.38
.33
.29
.26
.23
.20
.19
.64
.55
.48
.42
.37
.33
.30
.27
.25
.23
.60
.49
.42
.36
.31
.27
.24
.21
.19
.17
.55
.47
.41
.36
.32
.29
.26
.24
.22
.20
.52
.43
.36
.31
.27
.24
.21
.19
.17
.15
From 0° AveLumens
0
5
15
25
35
45
55
65
75
85
90
638
659
683
667
551
467
405
372
368
370
370
63
195
305
346
362
364
371
390
404
50% beam angle
68.1°
10% beam angle
114.0°
Mount
height
Inital fc
at beam
center
Beam
diameter
fc at
beam
edge
Beam
diameter
fc at
beam
edge
8
10
12
14
16
21.1
11.3
7.1
4.8
3.5
7.4
10.1
12.8
15.5
18.2
10.5
5.7
3.5
2.4
1.8
16.9
23.1
29.2
35.4
41.5
2.1
1.1
0.7
0.5
0.4
PHOTOMETRY NOTES
• Tested to current IES and NEMA standards under stabilized laboratory conditions.
• Actual performance may differ as a result of end-user environment and application.
• Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
Comentarios a estos manuales