AFZW-8-XBAFFLE
PHOTOMETRY
8” AFZW
Cross Baffle Trim
Low Profile, Double Twin-Tube
PHOTOMETRY NOTES
• Tested to current IES and NEMA standards under stabilized laboratory condition.
• Actual performance may differ as a result of end-user environment and application.
• Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
Fixture/Lamp Candlepower Data Footcandle values
TECHNICAL INFORMATION
Footcandle values are initial and tables are based on minimum of six units. For fixture-to-wall
distance other than those shown, use maximum of one-to-one spacing (distance between fixtures not
more than distance to wall) for best results.
90
0
112
0
1
2
135
0
157
0
1
2
67
0
1
2
45
0
22
0
1
2
Plane Angle
Wall 22.5 45 67.590112.5135 157.5
0
5
15
25
35
45
55
65
75
85
90
1157
1126
1104
1023
734
516
255
129
63
26
0
1157
1121
1106
1042
680
404
185
92
45
4
0
1157
1129
1069
842
525
222
48
8
0
0
0
1157
1143
1056
861
456
159
35
0
0
0
0
1157
1156
1093
866
498
150
9
0
0
0
0
1157
1189
1170
901
528
177
21
0
0
0
0
1157
1217
1247
1114
525
125
1
0
0
0
0
1157
1245
1335
1170
559
102
0
0
0
0
0
Vertical Angle
Wallwash Illuminance Study (fc)
Illuminance on wall from 6 luminaires
Luminaire
mounted 3 ft.
from wall
Luminaire
mounted 4 ft.
from wall
3 ft. between
luminaires
4 ft. between
luminaires
ft. from ceiling33.54 33.5 4
1
2
3
4
5
6
7
8
9
10
11
9
15
22
22
21
19
16
13
11
9
8
6
12
19
22
21
19
17
14
11
9
8
9
15
22
22
21
19
16
13
11
9
8
3
6
11
13
13
12
12
10
9
8
7
2
5
8
11
12
12
12
11
10
8
7
3
6
11
13
13
12
12
10
9
8
7
2/26DTT 84A
PL-C 26W/27K lamps
total rated lumens
No. 2193122101