GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 07/31/13. Specifications subject to change without notice.
PAGE 4 OF 4
CHU-8-OPEN-PAR
PHOTOMETRY
CHU8 P38100M 6AR
MP100PAR38/U/FL35/ECO LAMP, 0.6 S/MH, 5800 RATED LUMENS, TEST NO. LTL19287
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
8” CHU
Up/Down, Wall-Mounted Cylinder
PAR Metal Halide, 6” Aperture
60°
80°
100°
120°
140° 160°180°
Ave Lumens
0
5
15
25
35
45
55
65
75
85
90
11649
10525
7244
1877
157
16
3
1
1
0
0
953
1908
921
133
16
3
1
1
0
Zone Lumens% Lamp
0° - 30°
0° - 40°
0° - 60°
0° - 90°
90° - 120°
90° - 130°
90° - 150°
90° - 180°
0° - 180°
3781.9
3914.8
3933.3
3935.4
5.4
10.8
120.4
3509.8
7445.2
32.6
33.7
33.9
33.9
0.0
0.1
1.0
30.3
*64.2
*Efficiency
pc 80% 70% 50%
pw 50% 30% 10% 50% 30% 10% 50% 30% 10%
0
1
2
3
4
5
6
7
8
9
10
69
63
58
54
50
47
44
41
39
37
35
69
61
55
50
46
43
40
37
35
33
32
69
60
53
48
44
40
37
35
33
31
29
64
59
54
50
47
44
42
39
37
35
34
64
57
52
48
44
41
38
36
34
32
31
64
56
50
45
42
39
36
34
32
30
29
55
51
47
45
42
40
38
36
34
33
31
55
50
46
43
40
37
35
33
32
30
29
55
49
44
41
38
35
33
31
30
28
27
RCR
50% beam -
32.3°
10% beam -
51.9°
Mounting
Height
Inital FC
Center
Beam Diameter FC Diameter FC
8.0
10.0
12.0
14.0
16.0
385.1
207.1
129.1
88.1
63.9
3.2
4.3
5.5
6.7
7.8
192.5
103.5
64.5
44.0
32.0
5.4
7.3
9.2
11.2
13.1
38.5
20.7
12.9
8.8
6.4
PHOTOMETRY NOTES
• Tested to current IES and NEMA standards under stabilized laboratory conditions.
• Actual performance may differ as a result of end-user environment and application.
• Consult factory or IES file for microgroove baffle, black cone or other photometric reports.